Dow-Key Microwave MS-1U18S-4 Manual do Operador

Consulte online ou descarregue Manual do Operador para Comutadores de rede Dow-Key Microwave MS-1U18S-4. Dow-Key Microwave MS-1U18S-4 Operator`s manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - 1U MS, MP, CB Matrix Series

“There Is No Substitute for Experience” DOW-KEY MICROWAVE 1U MS, MP, CB Matrix Series MS-1U18S-4/6-ENET CAN BUS RF SWITCH MATRIX Operator’s Manua

Página 2

4 General Information 1.4 CB Matrices CB-Series stands for Crossbar. It is a matrix with several inputs connecting to several outputs. Only one input

Página 3 - WARRANTY

5 General Information 1.5 Technical Specifications Refer to appendix A

Página 4 - Manual Revision History

6 1.6 Safety Precaution Safety precautions should be observed before using this product and any associated instrumentation. This product is intende

Página 5 - Table of Contents

7 2 System Layout 2.1 Front Panel Layout Figure 2-1 shows the 1U Model general layout, which includes: • 2 handles • Three LED, LCD and keypad

Página 6

8 System Layout 2.2 Rear Panel Layout Figure 2-2 shows an example of a 1U model rear panel general layout. All models have common parts which includ

Página 7 - 1 General Information

9 System Layout System Layout 2.3 Top View Layout Figure 2-3 shows the top view layout of all models. Figure 2-3, Top View of 1U Models

Página 8 - 1.2 MS Matrices

10 System Layout 2.4 RF configuration Refer to appendix B.

Página 9 - 1.3 MP Matrices

11 3 Connections 3.1 Power Connection 3.1.1 Line Voltage The matrix operates from a line voltage in the range of 110V to 240V at a frequency of 50 o

Página 10 - 1.4 CB Matrices

12 Connections Insert small bladed screwdriver to release the fuse. Figure 3-1, Power Entry Module Line Voltage Fuse Rating Manufacturer Manufactu

Página 11 - 1.5 Technical Specifications

13 Connections Pin 1 NC Pin 2 Transmit Pin 3 Receive Pin 4 NC Pin 5 Ground Pin 6 NC Pin 7 NC Pin 8 NC Pin 9 NC Table 3-2, RS232 Female Conne

Página 12 - 1.9 Repacking for shipment

Copyright © Dow-Key Microwave Corporation 2012, all rights reserved. Information in this publication supersedes that in all previously published mate

Página 13 - 2 System Layout

14 Connections 3.5 Ethernet Connection The matrix comes equipped with an Ethernet port (RJ45 connector) which allows the user to easily access the ma

Página 14 - 2.2 Rear Panel Layout

15 4 Configuring the Matrix for Operation 4.1 Matrix Configuration The ‘brain’ inside Dow-Key Matrices, referred to as the “Matrix Controller”, has b

Página 15 - 2.3 Top View Layout

16 Configuring the Matrix 4.3 Adding and Deleting Switches The following rules apply when adding a switch to the Matrix Configuration (the desired I

Página 16 - 2.4 RF configuration

17 Configuring the Matrix Example procedure: Adding a switch to the Configuration usually starts by finding the ID of the physical switch to add. Se

Página 17 - 3 Connections

18 Configuring the Matrix 4.5 Connection to an Ethernet The use of a standard “Straight Through” Ethernet cable is required to connect the matrices

Página 18 - 3.3 RS232 Connection

19 Configuring the Matrix 4.5 Testing Ethernet Communication The matrix’s ability to communicate should be tested once it has been configured and co

Página 19 - 3.4 CAN Bus Connection

20 Configuring the Matrix In both the above scenarios a valid and working connection will yield a response similar that shown in the example below:

Página 20 - 3.6 USB Port

21 5 Manual (LOCAL) Operation 5.1 The Keypad / LCD Interface Power On: Position the rocker switch on the rear panel of the Matrix to the on positi

Página 21 - 4.1 Matrix Configuration

22 Manual (LOCAL) Operation UP and DOWN serve as “scroll up”, “scroll down”, “increment”, or “decrement”. Many data fields’ values are modified by

Página 22

23 Manual (LOCAL) Operation 5.2 Main Menu 5.2.1 Switching Operations Switch Operations Menu Set Switch Positions View the currently set position a

Página 23

iii WARRANTY Dow-Key Microwave Corporation warrants this product to be free from defects in material and workmanship for a period of 1 year from date

Página 24

24 Manual (LOCAL) Operation Recall Positions Recall from non-volatile memory the state of the positions of all switch ID’s configured to the matrix,

Página 25

25 Manual (LOCAL) Operation 5.2.2 Error Operations View the contents of the Error Log (see Section 6.5.1). Each entry is displayed with the oldest b

Página 26

26 Manual (LOCAL) Operation 5.2.3 System Settings System Settings Menu ! Important Note: The matrix controller is designed to offer the maximum expa

Página 27 - 5 Manual (LOCAL) Operation

27 Manual (LOCAL) Operation 4. NOTE: this operation “puts the matrix’s switches to sleep” thereby rendering the matrix inoperable during the proces

Página 28

28 Manual (LOCAL) Operation 5.2.4 Ethernet Options Actual changes to the Ethernet variables referred to below will not take effect nor be shown on t

Página 29 - 5.2 Main Menu

29 Manual (LOCAL) Operation 5.2.5 LCD Options View and adjust the brightness and contrast of the LCD. Changes made here are persistent over power d

Página 30

30 6 Remote Operation 6.1 Introduction to SCPI SCPI is a command structure that is based on the IEEE-488.2 specification which Dow-key has adapte

Página 31

31 Remote Operation 6.3 Command Separators and conventions • A colon (:) is used to separate a command keyword from a lower level keyword. • A bla

Página 32

32 Remote Operation 6.4 Common Commands The following contains the common commands of SCPI that the Ethernet controller is compatible with. The poss

Página 33

33 Remote Operation 6.4.2 *OPC? Syntax *OPC? Description This query returns an ASCII character “1” when all pending operations have been finished.

Página 34

iv Manual Revision History The revision history shown below lists all revisions and addendums created for this manual. The revision level increases n

Página 35

34 Remote Operation 6.4.3 *RST Syntax *RST Description This command performs a device reset. This will set the instrument so that all switches are

Página 36 - 6 Remote Operation

35 Remote Operation Example “SYST:ERR?” Result was “1, INVALID CHARACTER”, check for more errors. Description: This error is no longer supporte

Página 37

36 Remote Operation SYST:ERR?” Result was “10, SWITCH DID NOT RESPOND”, check for more errors. Description: One of the switches did not respond to a

Página 38

37 Remote Operation SYST:ERR?” Result was “30, COMMAND UNRECOGNIZED”, check for more errors. Description: This error code is generated when the comm

Página 39

38 Remote Operation 6.5.2 SYST:IPADDRESS? Syntax SYSTem:IPADDRESS? Description Returns the matrix IP address. Result xxx.yyy.zzz.aaa Possible err

Página 40

39 Remote Operation 6.5.4 SYST:TCPPORT? Syntax SYSTem:TCPPORT? Description Returns the matrix TCP Port number. Result n Possible error codes No

Página 41

40 Remote Operation 6.5.6 SYST:GATEWAY? Syntax SYSTem:GATEWAY? Description Returns the matrix gateway address. Result xxx.yyy.zzz.aaa Possible er

Página 42

41 Remote Operation 6.5.7 SYST:GATEWAY xxx.yyy.zzz.aaa Syntax SYSTem:GATEWAY xxx.yyy.zzz.aaa Description Sets matrix gateway address to xxx.yyy.zzz

Página 43

42 Remote Operation 6.5.9 SYST:MASK xxx.yyy.zzz.aaa Syntax SYSTem:MASK xxx.yyy.zzz.aaa Description Sets the matrix subnet mask address to xxx.yyy.z

Página 44

43 Remote Operation 6.5.11 SYST:SERIALNUMBER? Syntax SYSTem:SERIALNUMBER? Description Returns the matrix serial number. Result n Possible error c

Página 45

v Table of Contents 1 General Information ... 11.

Página 46

44 Remote Operation 6.5.13 SYST:TIMEOUT x Syntax SYSTem:TIMEOUT x Description The Timeout is used to automatically close the TCP/IP socket after a

Página 47

45 Remote Operation 6.5.14 SYST:STATUS? Syntax SYSTem:STATUS? Description This command will return all Switch positions, Local/Remote mode, Power s

Página 48

46 Remote Operation 6.5.15 SYST:SCREENSAVER? Syntax SYSTem:SCREENSAVER? Description This command will return the screen saver time settings n (n is

Página 49

47 Remote Operation 6.6 Switch [Module] Command Set The following contains the switch [module] commands of SCPI that the Ethernet control is compat

Página 50

48 Remote Operation 6.6.2 Setting switch x to position n x = switch [module] address. n = position to set and must be within the switches parameter

Página 51

49 Remote Operation 6.6.3 Requesting Switch x current position x = switch address. Examples: • ROUTE:SWITCHx? • ROUT:SWITx? • :SWITx? Result: Retu

Página 52

50 Remote Operation 6.7 DHCP Command Set The following contains the DHCP (Dynamic Host Configuration Protocol) commands of SCPI that the Ethernet c

Página 53

51 Remote Operation This page intentionally left blank

Página 54

52 RS232, USB and Ethernet Command description for standard matrices Command Syntax Response Action 1 *IDN? MS-1U18S-4/6-ENET Returns string in ’

Página 55

53 Remote Operation Note: 1. Commands are NOT case sensitive. 2. Every command and response on the Ethernet and serial port should have “\r\n” Car

Página 56

vi 6.4.3 *RST ... 346.5 System Commands ...

Página 57 - Remote Operation

54 7 Web Page Server (HTTP) 7.1 Web Page Server Control The matrix may be controlled by way of web pages served by the matrix over its Ethernet port

Página 58

55 Web Page Server 7.2 Matrix Control Clicking on ‘Matrix control’ will show the below page. Remote mode commands may be typed into the Command tex

Página 59

56 Web Page Server 7.3 Matrix Configuration Clicking on ‘Matrix configuration’ will show the below page. ! Important Note: The matrix controller i

Página 60 - 7 Web Page Server (HTTP)

57 Web Page Server 7.4 Matrix Status Clicking on ‘Matrix status’ will show the below page. This page displays the current status of alarm sources

Página 61 - 7.2 Matrix Control

58 Appendix A Technical Specifications Model: MS-1U18S-4/6-ENET Configuration: Four SP6T switches mounted on the rear panel RF Connectors:

Página 62 - 7.3 Matrix Configuration

59 Appendix B RF Configuration Model: MS-1U18S-4/6-ENET Four normally open SP6T switches (Dow-Key part number: 565-5208-3-ROHS) mounted on the rear

Página 63 - 7.4 Matrix Status

1 1 General Information 1.1 Introduction The Dow-Key Microwave 1U MS, MP, CB Switch Matrix series are electromechanical RF matrices. They come equip

Página 64 - Appendix A

2 General Information 1.2 MS Matrices MS-Series stands for Multiple Switches. It is a matrix where a number of independent switches are populated on

Página 65 - Appendix B

3 General Information 1.3 MP Matrices MP-Series stands for Multiplexer. It is a matrix with one input connecting to many outputs (only one at the tim

Comentários a estes Manuais

Sem comentários