Página 1 - MS, MP, CB Matrix Series

i “There Is No Substitute for Experience” DOW-KEY MICROWAVE MS, MP, CB Matrix Series MS-2U18SFRL-4/X-GPIB CAN BUS RF SWITCH MATRIX Operator’s Manua

Página 2

4 General Information 1.4 CB Matrices CB-Series stands for Crossbar. It is a matrix with several inputs connecting to several outputs. Only one input

Página 3 - WARRANTY

5 General Information 1.5 Technical Specifications Refer to appendix A

Página 4 - Manual Revision History

6 General Information 1.6 Safety Precaution Safety precautions should be observed before using this product and any associated instrumentation. This

Página 5 - Table of Contents

7 2 System Layout 2.1 Front Panel Layout 2 Note: The matrices shown below are with the LCD on the front panel and rear mounted switches. Matrices wi

Página 6

8 System Layout 2.2 Rear Panel Layout for 2U models Figure 2-2 shows the general layout of the rear panel of a variety of 2U models. All models have

Página 7 - 1 General Information

9 System Layout 2.3 Rear Panel Layout for 3U models Figure 2-3 shows the general layout of the rear panel of a variety of 3U models. All models have

Página 8 - 1.2 MS Matrices

10 System Layout 3U MS series (with external switches) 3U MS series (with internal switches) or MP series or CB series 3U

Página 9 - 1.3 MP Matrices

11 System Layout 2.4 Rear Panel Layout for 4U models Figure 2-4 shows the general layout of the rear panel of a variety of 4U models. All models hav

Página 10 - 1.4 CB Matrices

12 System Layout 4U MS series (with external switches) 4U MS series (with internal switches) or MP series or CB series 4U MS seri

Página 11 - 1.5 Technical Specifications

13 System Layout 2.5 Top View Layout Figure 2-5 shows the top view layout of all models. Note: The dimension indicated on the drawing is for 3

Página 12 - 1.9 Repacking for shipment

ii Copyright © Dow-Key Microwave Corporation 2010, all rights reserved. Information in this publication supersedes that in all previously published m

Página 13 - 2 System Layout

14 System Layout 2.6 RF configuration Refer to appendix B.

Página 14

15 3 Connections 3.1 Power Connection 3.1.1 Line Voltage The matrix operates from a line voltage in the range of 110V to 240V at a frequency of 50 o

Página 15

16 Connections Insert small bladed screwdriver to release the fuse. Figure 3-1, Power Entry Module Line Voltage Fuse Rating Manufacturer Manufactu

Página 16

17 Connections 3.3 RS232 Connection The switch matrix may be operated over this connection (See Section 6 for a description of the commands). The RS

Página 17

18 Connections 3.4 CAN Bus Connection This connection allows the internal matrix controller to be easily interfaced to another Dow-Key Microwave Swit

Página 18

19 Connections 3.5 GPIB Control Connection On the rear panel of the matrix is a GPIB (IEEE-488) control port which gets connected to the GPIB port o

Página 19 - 2.5 Top View Layout

20 Connections 3.5.2 Interface Signals The GPIB (IEEE-488) interface system consists of 16 signal lines and 8 ground lines. The 16 signal lines are

Página 20 - 2.6 RF configuration

21 Connections 3.5.4 Handshake Lines The three handshake lines (NRFD, NDAC, DAV) control the transfer of message bytes among the devices and form th

Página 21 - 3 Connections

22 Connections The REN (Remote Enable) signal is asserted only by the System Controller. Its assertion does not place devices into remote control m

Página 22 - 3.2 Ground Connection

23 4 Configuring the Matrix for Operation 4.1 Matrix Configuration The ‘brain’ inside Dow-Key Matrices, referred to as the “Matrix Controller”, has b

Página 23 - 3.3 RS232 Connection

iii WARRANTY Dow-Key Microwave Corporation warrants this product to be free from defects in material and workmanship for a period of 1 year from date

Página 24 - 3.4 CAN Bus Connection

24 Configuring the Matrix 4.3 Adding and Deleting Switches The following rules apply when adding a switch to the Matrix Configuration (the desired I

Página 25 - 3.5 GPIB Control Connection

25 Configuring the Matrix Example procedure: Before adding it to the Configuration you need to find the switch’s ID. To do this select Main Menu>

Página 26

26 5 Manual (LOCAL) Operation 5.1 The Touch Screen Interface Power On: Position the rocker switch on the rear panel of the Matrix to the ON positi

Página 27

27 Manual (LOCAL) Operation The figure above shows the matrix LCD touch screen (sometimes referred to as the “User Interface”, or “UI”) a

Página 28 - 3.6 USB Port

28 Manual (LOCAL) Operation 5.2 Main Menu 5.2.1 Switching Operations Switch Operations Menu Set Switch Positions View the currently set position a

Página 29 - 4.1 Matrix Configuration

29 Manual (LOCAL) Operation Recall Positions Recall from non-volatile memory the state of the positions of all switch ID’s configured to the matrix,

Página 30

30 Manual (LOCAL) Operation 5.2.2 Error Operations View the contents of the Error Log (see Section 7.5.1). Each entry is displayed with the oldest b

Página 31

31 Manual (LOCAL) Operation 5.2.3 System Settings System Settings Menu ! Important Note: The matrix controller is designed to offer the maximum expa

Página 32 - 5 Manual (LOCAL) Operation

32 Manual (LOCAL) Operation 4. NOTE: this operation “puts the matrix’s switches to sleep” thereby rendering the matrix inoperable during the proces

Página 33

33 Manual (LOCAL) Operation 5.2.4 Ethernet Options Ethernet Menu Not applicable to GPIB (IEEE-488) models. This button is not operational. 5.2.5

Página 34 - 5.2 Main Menu

iv Manual Revision History The revision history shown below lists all revisions and addendums created for this manual. The revision level increases n

Página 35

34 6 IEEE 488.2 Register model 6.1 Introduction to IEEE 488.2 The topics discussed in sections 4.2 to 4.3 are for the most part transparent to

Página 36

35 IEEE 488.2 Register Model 6.5 The Status Byte Register The Status Byte register reports conditions from the other registers. Data in the instr

Página 37

36 IEEE 488.2 Register Model 6.6 The Standard Event Register The Standard Event Register reports different types of events that may occur in the in

Página 38

37 IEEE 488.2 Register Model 6.7 IEEE 488.2 Common Commands This matrix implements common commands that the IEEE-488.2 standard defines. The foll

Página 39

38 7 Remote Operation 7.1 Introduction to SCPI SCPI is a command structure that is based on the IEEE-488.2 specification which Dow-key has adapte

Página 40 - IEEE 488.2 Register model

39 Remote Operation 7.3 Command Separators and conventions • A colon (:) is used to separate a command keyword from a lower level keyword. • A bl

Página 41

40 Remote Operation 7.4 Common Commands The following contains the IEEE 488.2 common commands of SCPI that the GPIB controller is compatible with. T

Página 42

41 Remote Operation 7.4.3 *ESE? Syntax *ESE? Description This query allows the user to determine the current contents of Standard Event Statu

Página 43

42 Remote Operation 7.4.5 *IDN? Syntax *IDN? Result A string is returned which consists of the following parts: Model Model Matrix model num

Página 44 - 7 Remote Operation

43 Remote Operation 7.4.7 *OPC? Syntax *OPC? Description This query returns an ASCII character “1” when all pending operations have been finished.

Página 45

vi Table of Contents 1 General Information ... 11

Página 46

44 Remote Operation 7.4.8 *RST Syntax *RST Description This command performs a device reset. This will set the instrument so that all switches are

Página 47

45 Remote Operation 7.4.10 *SRE Syntax *SRE <enable_value> Parameters Enable_value Value that corresponds to the binary-weighted sum of the

Página 48

46 Remote Operation 7.5 System Commands The following contains the SCPI system commands that the GPIB, RS-232 and USB control is compatible with.

Página 49

47 Remote Operation Example “SYST:ERR?” Result was “1, INVALID CHARACTER”, check for more errors. Description: This error is no longer supporte

Página 50

48 Remote Operation SYST:ERR?” Result was “10, SWITCH DID NOT RESPOND,x”, check for more errors. Description: Switch x did not respond to a position

Página 51

49 Remote Operation SYST:ERR?” Result was “30, COMMAND UNRECOGNIZED”, check for more errors. Description: This error code is generated when the comm

Página 52

50 Remote Operation 7.5.2 SYST:SERIALNUMBER? Syntax SYSTem:SERIALNUMBER? Description Returns the matrix serial number. Result n Possible error co

Página 53

51 Remote Operation 7.5.3 SYST:STATUS? Syntax SYSTem:STATUS? Description This command will return all Switch positions, Local/Remote mode, Power s

Página 54

52 Remote Operation 7.5.4 SYST:SCREENSAVER? Syntax SYSTem:SCREENSAVER? Description This command will return the screen saver time settings n (n is

Página 55

53 Remote Operation 7.5.6 SYST:GPIBADDRESS? Syntax SYSTem:GPIBADDRESS? Description This command will return the matrix’s GPIB address. Possible va

Página 56

vi 6.2 Condition Register ... 346.3 Event Register ...

Página 57

54 Remote Operation 7.6 Switch [Module] Command Set The following contains the switch [module] commands of SCPI that the GPIB / RS 232 / USB con

Página 58

55 Remote Operation 7.6.2 Setting switch x to position n x = switch [module] address. n = position to set and must be within the switches paramete

Página 59

56 Remote Operation 7.6.3 Requesting Switch x current position x = switch address. Examples: • ROUTE:SWITCHx? • ROUT:SWITx? • :SWITx? Result: Ret

Página 60

57 Remote Operation This page intentionally left blank

Página 61

58 GPIB, RS232 and USB Command description for standard matrices Command Syntax Response Action 1 *IDN? MS-2U18S-3/10-GPIB Returns string in ’Mod

Página 62

59 Remote Operation Note: 1. Commands are NOT case sensitive. 2. For GPIB communication no ASCII termination is required, but the End Or Identify

Página 63 - Remote Operation

60 Appendix A Technical Specifications Model: MS-2U18SFRL-4/X-GPIB Configuration: 4 Transfer switches mounted on the front panel RF Connectors

Página 64

61 Appendix A Front View:

Página 65

62 Appendix B RF Configuration Model: MS-2U18SFRL-4/X-GPIB Four independent transfer switches (Dow-Key part number: 411L-420832N-ROHS) mounted on t

Página 66 - Appendix A

1 1 General Information 1.1 Introduction The Dow-Key Microwave MS, MP, CB Switch Matrix series are electromechanical RF matrices. They come equipped

Página 67

2 General Information 1.2 MS Matrices MS-Series stands for Multiple Switches. It is a matrix where a number of independent switches are populated on

Página 68 - Appendix B

3 General Information 1.3 MP Matrices MP-Series stands for Multiplexer. It is a matrix with one input connecting to many outputs (only one at the ti

Comentários a estes Manuais